Features |
|
Compliance | Standards: EN 60079 – 0, IS/ IEC / EN 60079 – 30 – 1 & EN 60079 – 31. |
Approvals |
Tested by Central Institute of Mining and Fuel Research (CSIR-CIMFR), Dhanbad and approved by Petroleum and Explosives Safety Organization ( PESO), Nagpur, India for Zone II , TI (ATEX) for Zone I / Division II & EAC for use in hazardous area applications. |
Safety | As the Cable self regulates its heat output, its limit the maximum sheath temperature, thus making it burnout proof. |
Specifications |
|||
Catalogue Reference | HTT30 | HTT45 | HTT60 |
Heating Power W/m (230V AC) at 10 C | 30 | 45 | 60 |
Voltage Supply | 230/240VAC, 50/60 Hz, 110/120VAC, Max. 500V on request. | ||
Max. Installation Temperature Power On | 180℃ | 165℃ | 150℃ |
Max. Exposure Temperature Power Off | 260℃ | ||
Min. Installation Temperature | -65℃ | ||
Minimum Bending Radius | 25mm |
# Thermopads reserves the right to modify the specifications in line with future improvements, updated standards or updated certifications
Catalog Number |
Output at 10 deg C | Max. Circuit Length | Circuit Breaker Size | Max. Maintenance Temperature |
Max. Exposure Temperature |
HTT-30 |
30 W/m |
84 | 16A | 1800C | 2500C |
130 | 20A | 1800C | 2500C | ||
180 | 32A | 1800C | 2500C | ||
190 | 40A | 1800C | 2500C | ||
HTT-45 |
45 W/m |
55 | 16A | 1650C | 2500C |
90 | 20A | 1650C | 2500C | ||
120 | 32A | 1650C | 2500C | ||
155 | 40A | 1650C | 2500C | ||
HTT-60 |
60 W/m |
45 | 16A | 1500C | 2500C |
70 | 20A | 1500C | 2500C | ||
90 | 32A | 1500C | 2500C | ||
115 | 40A | 1500C | 2500C |