Features | |
Compliance | Standards: EN 60079 – 0, IS/ IEC / EN 60079 – 30 – 1 & EN 60079 – 31 |
Approvals | Tested by Central Institute of Mining and Fuel Research (CSIR-CIMFR), Dhanbad and approved by Petroleum and Explosives Safety Organization ( PESO), Nagpur, India for Zone II , TI (ATEX) for Zone I / Division II & EAC for use in hazardous area applications |
Safety | As the Cable self regulates its heat output, its limit the maximum sheath temperature, thus making it burnout proof |
Specifications | ||||
Catalogue Reference | STP-15 / STP-M-15 | STP-30/STP-M-30 | STP-45/ STP-M-45 | STP-60/ STP-M-60 |
Heating Power W/m (230V AC) at 10oC | 15 | 30 | 45 | 60 |
Voltage Supply | 230/240 VAC, 50/60 Hz, 110/120VAC on request | |||
Max. Operating Temperature | 150⁰C (130⁰C for STP-M) | |||
Max. Exposure Temperature | 250⁰C (230⁰C for STP-M) | |||
Min. Installation Temperature | – 65⁰C | |||
Minimum Bending Radius | 25 mm |
# Thermopads reserves the right to modify the specifications in line with future improvements, updated standards or updated certifications
Catalog Number | Output at 10 deg C | Max. Circuit Length | Circuit Breaker Size | Max.Maintenance Temperature (STP) | Max. Exposure Temperature (STP) | Max. Maintenance temperature (STP-M) | Max. Exposure Temperature (STP-M) |
STP-15 |
15 W/m | 117 | 16A | 1500C | 2500C | 1300C | 2300C |
152 | 20A | 1500C | 2500C | 1300C | 2300C | ||
185 | 25A | 1500C | 2500C | 1300C | 2300C | ||
STP-30 |
30 W/m | 68 | 16A | 1500C | 2500C | 1300C | 2300C |
91 | 20A | 1500C | 2500C | 1300C | 2300C | ||
114 | 25A | 1500C | 2500C | 1300C | 2300C | ||
STP-45 |
45 W/m | 48 | 16A | 1500C | 2500C | 1300C | 2300C |
65 | 20A | 1500C | 2500C | 1300C | 2300C | ||
82 | 25A | 1500C | 2500C | 1300C | 2300C | ||
STP-60 |
60 W/m | 38 | 16A | 1500C | 2500C | 1300C | 2300C |
51 | 20A | 1500C | 2500C | 1300C | 2300C | ||
64 | 25A | 1500C | 2500C | 1300C | 2300C |